Loading

FactoryTalk® Service Platform Elevated Privileges Vulnerability Through Web Service Functionality

Severity:
Critical
Advisory ID:
SD1662
發佈日期:
February 14, 2024
最近更新:
December 04, 2024
Revision Number:
1.0
Known Exploited Vulnerability (KEV):
否
Corrected:
否
Workaround:
否
CVE IDs
CVE-2024-21915
下載
The following link(s) provide the security advisory in Vulnerability Exploitability Exchange format:
CVE-2024-21915
摘要
FactoryTalk® Service Platform Elevated Privileges Vulnerability Through Web Service Functionality

Published Date: February 15, 2024
Last updated:  February 15, 2024
Revision Number: 1.0
CVSS Score: 9.0/10

The security of our products is important to us as your chosen industrial automation supplier.  This vulnerability was found internally during routine testing and is being reported based on our commitment to customer transparency.

AFFECTED PRODUCTS AND SOLUTION

Affected Product

First Known in software version

Corrected in software version

FactoryTalk® Service Platform

             <v2.74

Update to V2.74 or later


VULNERABILITY DETAILS

Rockwell Automation used version 3.1 of the CVSS scoring system to assess the following vulnerabilities.

CVE-2024-21915 IMPACT

A privilege escalation vulnerability exists in FactoryTalk® Service Platform (FTSP). If exploited, a malicious user with basic user group privileges could potentially sign into the software and receive FTSP Administrator Group privileges. A threat actor could potentially read and modify sensitive data, delete data and render the FTSP system unavailable.

CVSS Base Score: 9.0
CVSS Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:CC:H/I:H/A:H
CWE: CWE-279: Incorrect Execution-Assigned Permissions

Known Exploited Vulnerability (KEV) database:  No

Customers can use Stakeholder-Specific Vulnerability Categorization to generate more environment specific prioritization.

Mitigations and Workarounds

Customers using the affected software are encouraged to apply the risk mitigations, if possible. Additionally, we encourage customers to implement our suggested security best practices to minimize the risk of vulnerability.

  • Security Best Practices

ADDITIONAL RESOURCES

  • Patch: Incorrect user groups returned from FactoryTalk® Web Service, FactoryTalk® Services Platform 2.74
  • JSON CVE-2024-21915
Rockwell Automation Home
Copyright ©2022 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left 台灣, 中國 Chevron RightChevron Right
  2. Chevron LeftChevron Left Trust Center Chevron RightChevron Right
  3. Chevron LeftChevron Left Industrial Security Adv Chevron RightChevron Right
  4. Chevron LeftChevron Left Industrial Security Advisory Detail Chevron RightChevron Right
請更新您的 cookie 設定以繼續.
此功能需要 cookie 來改善您的體驗。請更新您的設定以允許這些 cookie:
  • 社群媒體Cookie
  • 功能Cookie
  • 性能Cookie
  • 行銷Cookie
  • 全部Cookie
您可以隨時更新您的設定。想了解更多訊息,請參閱我們的 隱私政策
CloseClose