Loading

440G TLS-Z GD2
Allen-Bradley

The TLS-Z GD2 Guard Locking Switch is an interlock switch that has a uniquely coded RFID door sensor with inductive door position sensing technology.
Loading
  1. Product Selection
  2. Overview
  3. Documentation
Open All Close All
Product Selection Chevron DownChevron Down
篩選與過濾
CloseClose
篩選與優化
清除全部
排序方式 Chevron UpChevron Up
Chevron UpChevron Up
-
觀看 結果
顯示 1 - 1 / 0 結果
排序方式:
篩選與優化
最暢銷
Chevron UpChevron Up
產品資訊 產品配置 新增到項目

每頁項目:
1 - 1 / 0 結果
CloseClose
比較產品數量:
0
CloseClose
CloseClose
CloseClose
CloseClose
清除全部
立即比較 (0)
Overview Chevron DownChevron Down
Allen Bradley

Our TLS-Z GD2 Guard Locking Switch is an interlock switch that has a uniquely coded RFID door sensor with inductive door position sensing technology. This switch can detect if an actuator key breaks or becomes separated from its door mounted position. Built with the same solid-state technology as the TLS GD2, this switch supports the highest level of safety – Performance Level “e” (Ple) to EN ISO 13849-1.

  • Meets PLe to ISO 13849-1
  • Solid-state OSSD outputs series connectable to ISO 14119
  • RFID uniquely coded door target
  • Available in Power to Release or Power to Lock models
  • Easy QD connection
  • Same mechanical arrangement as standard 440G TLS-GD2 guard locking switch 
  • High locking force ≤2000 N (450 lbf)
Additional Information

Protect your people, productivity, and environment with our Safety Components and integrated Safety Solutions. We understand your factory floor challenges and can help you meet your goals with one of the broadest safety portfolios in the industry.

 


Specifications

DownloadDownload
TLSZR/L-GD2 Guard Locking Switch Installation Instructions
Certifications
UL Listed Component Mark Canadian and United States RequirementsUL Listed Component Mark Canadian and United States Requirements
FS Engineer (TÜV Rheinland) CertificateFS Engineer (TÜV Rheinland) Certificate
  • CE Marked for all applicable directives
  • cULus Listed
  • TÜV Certified
Safety Classification
  • Type 4 interlocking device with guard locking per ISO 14119 
  • High (unique) coding per ISO 14119
  • PLe Cat 4 per ISO 13849-1
Functional Safety Data (related to Safety Contacts)
  • PFHD  1.70E-09 Probability of dangerous failure per hour according to EN/IEC 61508 or EN/IEC 62061 (Continuous and High demand mode)
  • Dual channel interlock may be suitable for use in application up to PLe (according to ISO 13849-1) and for use up to SIL3 systems (according to IEC 62061) depending on application characteristics.
  • Mission time/PTI: 20 years or 106 cycles
Standards Compliance
  • ISO 14119
  • IEC 60947-5-3
  • ISO 13849-1

Certifications apply when product is marked. See our Product Certification site for Declarations of Conformity, certificates and other certification details. 

Looking for Additional Information?

To find additional product information including CAD drawing files, 3D models and more use our Product Catalog.

Product Catalog
Documentation Chevron DownChevron Down
Technical Specifications 出版物
Safety Switches Specifications Technical Data SWITCH-TD001_-EN-P
Installation Instructions 出版物
TLSZR/L-GD2 Guard Locking Switch Installation Instructions 440G-IN016_-ZH-P
User Manuals 出版物
Bulletin 440G TLSZ Guardmaster Guard Locking Switch User Manual 440G-UM002_-EN-P
Product Profiles 出版物
TLS-Z GD2 Safety Guard Locking Switches Product Profile 440GZ-PP001_-EN-P
Miscellaneous 出版物
Safety Switches Brochure GLSAFE-BR002_-ZH-P
  1. Chevron LeftChevron Left 台灣, 中國 Chevron RightChevron Right
  2. Chevron LeftChevron Left 產品 Chevron RightChevron Right
  3. Chevron LeftChevron Left 硬體 Chevron RightChevron Right
  4. Chevron LeftChevron Left Safety Products Chevron RightChevron Right
  5. Chevron LeftChevron Left 440G TLS-Z GD2 Chevron RightChevron Right
請更新您的 cookie 設定以繼續.
此功能需要 cookie 來改善您的體驗。請更新您的設定以允許這些 cookie:
  • 社群媒體Cookie
  • 功能Cookie
  • 性能Cookie
  • 行銷Cookie
  • 全部Cookie
您可以隨時更新您的設定。想了解更多訊息,請參閱我們的 {0} 隱私政策
CloseClose