Product Family NEMA
Number of normally open contacts as main contact 3
Number of normally closed contacts as main contact 0
Voltage type for actuating AC
Rated control supply voltage at AC 50 Hz 440 V
Rated control supply voltage at AC 60 Hz 460 V
Type of electrical connection of main circuit Screw connection
Continuous ampere rating Tungsten load : 20 A
Breaker size, max 40A @ 480V AC service voltage
Voltage, max Tungsten load : 480V AC, 3-phase
Power, max 5VA @ 24V AC rated input voltage
Steady state current 91mA @ 200...277V AC rated input voltage
Control type Electrically held -no control module
Short circuit current rating 50kA @ 480V AC service voltage, SCCR RK1 fuse
Features Electrically/mechanically held lighting contactors
Modular version True
Surge transient peak 6 kV
Sealed coil rating 28 VA
EMI 35 V/m
Inrush coil rating 248 VA
Allowable leakage current, max 1.8 mA
Frequency 40 Hz
Auxiliary contact rating A600, 24V DC @ 24VA
Pulse duration, min 250 ms @ 3-wire control module
Storage temperature -30 °C
Operating temperature -25 to 40 °C
Enclosure type Open style
Wire size Power poles: 2 Cables, #14 AWG (solid or stranded) @ 75 °C Cu (#8 AWG stranded only)
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 0.0
Lead Time 1
Dimension Width 0.0
Dimension Length 0.0
Stock Status NON_STOCKED
Weight 3.024
Weight Unit KG
Tipo Recurso Publicação
General Product Cutsheet --
General Instruction Sheet --
General Dimension Sheet --
General Specifications Sheet --
Technical Data 500-td012_-en-p 500-TD012
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
Ítems por página:
1-1 de 1
Ítems por página:
1-1 de 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Product Family NEMA
Number of normally open contacts as main contact 3
Number of normally closed contacts as main contact 0
Voltage type for actuating AC
Rated control supply voltage at AC 50 Hz 440 V
Rated control supply voltage at AC 60 Hz 460 V
Type of electrical connection of main circuit Screw connection
Continuous ampere rating Tungsten load : 20 A
Breaker size, max 40A @ 480V AC service voltage
Voltage, max Tungsten load : 480V AC, 3-phase
Power, max 5VA @ 24V AC rated input voltage
Steady state current 91mA @ 200...277V AC rated input voltage
Control type Electrically held -no control module
Short circuit current rating 50kA @ 480V AC service voltage, SCCR RK1 fuse
Features Electrically/mechanically held lighting contactors
Modular version True
Surge transient peak 6 kV
Sealed coil rating 28 VA
EMI 35 V/m
Inrush coil rating 248 VA
Allowable leakage current, max 1.8 mA
Frequency 40 Hz
Auxiliary contact rating A600, 24V DC @ 24VA
Pulse duration, min 250 ms @ 3-wire control module
Storage temperature -30 °C
Operating temperature -25 to 40 °C
Enclosure type Open style
Wire size Power poles: 2 Cables, #14 AWG (solid or stranded) @ 75 °C Cu (#8 AWG stranded only)
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability false
Quick Turnaround false
Dimension Height 0.0
Lead Time 1
Dimension Width 0.0
Dimension Length 0.0
Stock Status NON_STOCKED
Weight 3.024
Weight Unit KG
Documentos
Product Cutsheet General
--
Instruction Sheet General
--
Dimension Sheet General
--
Specifications Sheet General
--
500-td012_-en-p Technical Data
500-TD012
Tipo Recurso Publicação
General Product Cutsheet --
General Instruction Sheet --
General Dimension Sheet --
General Specifications Sheet --
Technical Data 500-td012_-en-p 500-TD012
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
Accessories
Ítems por página:
1-1 de 1
Alternative Products
Ítems por página:
1-1 de 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
NEMA Modular Lighting Contactor
CloseClose
500LG-300A5-E
Fechar
Imprimir
Allen-Bradley 500LG-300A5-E product image
Telefone:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Brasil Chevron RightChevron Right
  2. Chevron LeftChevron Left Produtos Chevron RightChevron Right
Atualize suas preferências de cookies para continuar.
Este recurso requer cookies para melhorar sua experiência. Atualize suas preferências para permitir esses cookies:
  • Cookies de Redes Sociais
  • Cookies Funcionais
  • Cookies de Desempenho
  • Cookies de Marketing
  • Todos os Cookies
Você pode atualizar suas preferências a qualquer momento. Para mais informações, consulte nosso {0} Política de Privacidade
CloseClose