FactoryTalk® Remote Access™ has Unquoted Executables

Severity:
High
Advisory ID:
SD1671
公開日:
May 07, 2024
最終更新日:
December 04, 2024
Revision Number:
1.0
Known Exploited Vulnerability (KEV):
いいえ
Corrected:
はい
Workaround:
いいえ
CVE IDs
CVE-2024-3640
ダウンロード
The following link(s) provide the security advisory in Vulnerability Exploitability Exchange format:
JSON
概要
FactoryTalk® Remote Access™ has Unquoted Executables

Published Date: May 14, 2024

Last updated: May 14, 2024

Revision Number: 1.0

CVSS Score: v3.1: 7.7/10, v4.0: 7.0

 

AFFECTED PRODUCTS AND SOLUTION

 

 

Affected Product

 

 

 

 

First Known in software version

 

 

 

 

Corrected in software version

 

 

 

 

FactoryTalk® Remote Access™ (FTRA)

 

 

 

 

v13.5.0.174

 

 

 

 

V13.6  

 

 

 

VULNERABILITY DETAILS

Rockwell Automation used version 3.1 and 4.0 of the CVSS scoring system to assess the following vulnerabilities. 

CVE-2024-3640 IMPACT

An unquoted executable path exists in the affected products, possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a System user. A threat actor needs admin privileges to exploit this vulnerability. 

 

CVSS Base Score v3.1: 6.5/10

CVSS Vector String: CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H

CWE: CWE-428: Unquoted Search Path or Element

 

CVSS Base Score v4.0: 7.0/10

CVSS Vector String 4.0: CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

 

Known Exploited Vulnerability (KEV) database:  No

 

Users can use Stakeholder-Specific Vulnerability Categorization to generate more environment specific prioritization.

 

Mitigations and Workarounds 

Users using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices below, where possible. 

  • Security Best Practices 

 

 ADDITIONAL RESOURCES

The following link provides CVE information in Vulnerability Exploitability Exchange (VEX) format, which is machine readable and can be used to automate vulnerability management and tracking activities.     

 

  • JSON CVE-2024-3640

 

Rockwell Automation Home
Copyright ©2022 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left ロックウェル・オートメーションのホーム Chevron RightChevron Right
  2. Chevron LeftChevron Left Trust & Security Chevron RightChevron Right
  3. Chevron LeftChevron Left Industrial Security Adv Chevron RightChevron Right
  4. Chevron LeftChevron Left Industrial Security Advisory Detail Chevron RightChevron Right
を続行するには、クッキーの設定を更新してください.
この機能には、お客様の利便性を向上させるためにクッキーが必要です。これらのクッキーを許可するように設定を更新してください:
  • ソーシャルメディア・クッキー
  • 機能性クッキー
  • パフォーマンスクッキー
  • マーケティングクッキー
  • 全てのクッキー
いつでも設定を更新することができます。詳しくは{0}をご覧ください プライバシーポリシー
CloseClose