Loading

PN1629 | Denial-of-Service Vulnerability in FactoryTalk® Transaction Manager

Severity:
High
Advisory ID:
PN1629
公開日:
June 13, 2023
最終更新日:
June 13, 2023
Revision Number:
1.0
Known Exploited Vulnerability (KEV):
いいえ
Corrected:
いいえ
Workaround:
いいえ
CVE IDs
CVE-2023-2778
概要
Denial-of-Service Vulnerability in FactoryTalk® Transaction Manager

Revision History
Revision Number
1.0
Revision History
Version 1.0 - June 13, 2023

Affected Products

Affected Product First Known in Software Version Corrected in Software Version
FactoryTalk® Transaction Manager <=v13.10 BF29042 - Patch: Multiple issues, FactoryTalk Transaction Manager 13.00/13.10

Vulnerability Details

Rockwell Automation used the latest version of the CVSS scoring system to assess the following vulnerabilities. The security of our products is important to us as your chosen industrial automation supplier.  This anomaly was found internally during routine testing and is being reported based on our commitment to customer transparency and to improve their business or production environments.

CVE-2023-2778 IMPACT
A denial-of-service (DoS) vulnerability exists in the affected products. This vulnerability can be exploited by sending a modified packet to port 400. If exploited, the application could potentially crash or experience a high CPU or memory usage condition, causing intermittent application functionality issues. The application would need to be restarted to recover from the DoS.

CVSS Base Score 7.5
CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CWE: CWE-400 Uncontrolled Resource Consumption


Known Exploited Vulnerability (KEV) database: No

Customers can use Stakeholder-Specific Vulnerability Categorization to generate more environment specific prioritization.

Risk Mitigation & User Action

Customers using the affected software are encouraged to apply the risk mitigations below, if possible. Additionally, we encourage our customers to implement our suggested security best practices to minimize the risk of the vulnerability.
  • Customers should follow the instructions in BF29042 - Patch: Multiple issues, FactoryTalk Transaction Manager 13.00/13.10 to install the patch to mitigate the issue.
  • QA43240 - Recommended Security Guidelines from Rockwell Automation

Additional Resources

  • CVE-2023-2778 JSON

Rockwell Automation Home
Copyright ©2022 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left ロックウェル・オートメーションのホーム Chevron RightChevron Right
  2. Chevron LeftChevron Left Trust & Security Chevron RightChevron Right
  3. Chevron LeftChevron Left Industrial Security Adv Chevron RightChevron Right
  4. Chevron LeftChevron Left Industrial Security Advisory Detail Chevron RightChevron Right
を続行するには、クッキーの設定を更新してください.
この機能には、お客様の利便性を向上させるためにクッキーが必要です。これらのクッキーを許可するように設定を更新してください:
  • ソーシャルメディア・クッキー
  • 機能性クッキー
  • パフォーマンスクッキー
  • マーケティングクッキー
  • 全てのクッキー
いつでも設定を更新することができます。詳しくは{0}をご覧ください プライバシーポリシー
CloseClose