Spécifications techniques
Electrical
Environmental
Certification
Construction
Mechanical
Dessins
Documents
Certifications
Accessoires
Notes techniques
With integrated under voltage release
No
Rated operating voltage
0 A
Type of control element
Turn button
Type of electrical connection of main circuit
Screw connection
Rated impulse withstand voltage (Uimp)
6 kV
Magnetic trip current
31.3 A
Short circuit current for group motor, max
30kA @ 480V
Motor current adjustment range
1.6...2.5 A
Short circuit current Icu, max
75kA @ 400V
Rated operational current (Ie)
2.5 A
Ultimate short circuit breaking capacity (Icu) per IEC
75kA @ 400V AC
Rated service short circuit breaking capacity (Ics) per IEC
50kA @ 400V AC
Insulation voltage (Ui)
Rated 690V
Hp rating, max
2Hp @ 575V, 3-phase
KW rating, max
AC-3: 1.8 kW @ 690V, 3-phase
Short circuit current rating
Type 1 coordination: 5kA @ 600V AC
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC
25A @ 690V AC
Branch circuit protection per NEC/CEC, max
UL 60947 manual motor controller: 175 A
Trip class
10 A
Fuse or circuit breaker size per NEC, max
UL 60947-4-1 manual motor controller: 175 A
Short circuit current, max
Type 2 coordination, IEC 60947-4-1: 50kA @ 400V
Fuse or circuit breaker per NEC, max
UL 60947-4-1 manual motor controller: 175 A
Short circuit current for group motor installation, max
UL 60947 manual motor controller: 5kA @ 600V
Short circuit current for motor disconnect, max
UL 60947 manual motor controller: 5kA @ 600V
Number of poles
3
With thermal protection
Yes
Phase failure sensitive
Yes
Max current Ie
32 A
Maximum operating voltage (UL)
600 V
Disconnect function per IEC/EN 60947-2
Yes
Rated operating voltage (Ue)
690V AC
Rated frequency
50/60 Hz
Number of operations
Mechanical: 100.000 cycles, Electrical: 100000 cycles (0.1...16 A), 50000 cycles (20...32 A)
Power loss
5.1 W @ 0.16...1.6 rated operating current, 5.4 @ 2.5...6.3 rated operating current, 7.2 @ 10...12 rated operating current, 8.4 @ 16...25 rated operating current, 9.3 @ 32 rated operating current
Altitude
2000 m
Pollution degree
3
Storage ambient air temperature
-50 °C
Operating ambient air temperature
Open compensated: -25...+55 °C, Open: -25...+70 °C, Enclosed: 0...+40 °C
Utilization category
Circuit breaker: A per IEC60947-2, Motor starter: AC-3 per IEC60947-4-1
Device construction
Built-in device fixed built-in technique
Mounting
DIN Rail (EN 60715)
Group mounting side by side
Up to 40 °C (104 °F)
Resistance to shock
25 G/11 ms per IEC 60068-2-27
Resistance to vibration
5 G/3 ... 150 Hz per IEC 60068-2-6
Degree of protection
Housing: IP20, Main terminals: IP10
Dessins
3-Dimensional STEP model (STP) Télécharger (ZIP)
2-Dimensional Drawing (PDF) Télécharger (PDF)
Dessins
3-Dimensional STEP model (STP) Télécharger (ZIP)
2-Dimensional Drawing (PDF) Télécharger (PDF)
Taper Ressource Publication
Données techniques 140mp-td002_-en-p 140MP-TD002
Général Product Cutsheet --
Général Link to Literature Library for Tech Data 140MP-TD001
Vous recherchez plus de documentation ?
Recherchez une documentation technique organisée pour ce produit dans le Centre de documentation technique ou recherchez dans notre bibliothèque documentaire complète.
Rechercher dans la bibliothèque littéraire
IECEE Scheme UL Listed China CCC
  • IECEE Scheme
  • CE
  • UL Listed
  • Registro Italiano Navale
  • China CCC

Ce produit a été certifié conforme aux certifications mentionnées ci-dessus en date du 2025-07-19. Les produits vendus avant ou après cette date peuvent présenter des certifications différentes. Veuillez consulter l'étiquette du produit pour vérifier les certifications dont il dispose.

Articles par page:
1-1 de 1
Vous recherchez plus de notes techniques ?
Trouvez des questions et des réponses des experts techniques de Rockwell Automation pour ce produit dans notre base de connaissances.
Rechercher dans la base de connaissances
Spécifications techniques
With integrated under voltage release
No
Rated operating voltage
0 A
Type of control element
Turn button
Type of electrical connection of main circuit
Screw connection
Rated impulse withstand voltage (Uimp)
6 kV
Magnetic trip current
31.3 A
Short circuit current for group motor, max
30kA @ 480V
Motor current adjustment range
1.6...2.5 A
Short circuit current Icu, max
75kA @ 400V
Rated operational current (Ie)
2.5 A
Ultimate short circuit breaking capacity (Icu) per IEC
75kA @ 400V AC
Rated service short circuit breaking capacity (Ics) per IEC
50kA @ 400V AC
Insulation voltage (Ui)
Rated 690V
Hp rating, max
2Hp @ 575V, 3-phase
KW rating, max
AC-3: 1.8 kW @ 690V, 3-phase
Short circuit current rating
Type 1 coordination: 5kA @ 600V AC
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC
25A @ 690V AC
Branch circuit protection per NEC/CEC, max
UL 60947 manual motor controller: 175 A
Trip class
10 A
Fuse or circuit breaker size per NEC, max
UL 60947-4-1 manual motor controller: 175 A
Short circuit current, max
Type 2 coordination, IEC 60947-4-1: 50kA @ 400V
Fuse or circuit breaker per NEC, max
UL 60947-4-1 manual motor controller: 175 A
Short circuit current for group motor installation, max
UL 60947 manual motor controller: 5kA @ 600V
Short circuit current for motor disconnect, max
UL 60947 manual motor controller: 5kA @ 600V
Number of poles
3
With thermal protection
Yes
Phase failure sensitive
Yes
Max current Ie
32 A
Maximum operating voltage (UL)
600 V
Disconnect function per IEC/EN 60947-2
Yes
Rated operating voltage (Ue)
690V AC
Rated frequency
50/60 Hz
Number of operations
Mechanical: 100.000 cycles, Electrical: 100000 cycles (0.1...16 A), 50000 cycles (20...32 A)
Power loss
5.1 W @ 0.16...1.6 rated operating current, 5.4 @ 2.5...6.3 rated operating current, 7.2 @ 10...12 rated operating current, 8.4 @ 16...25 rated operating current, 9.3 @ 32 rated operating current
Altitude
2000 m
Pollution degree
3
Storage ambient air temperature
-50 °C
Operating ambient air temperature
Open compensated: -25...+55 °C, Open: -25...+70 °C, Enclosed: 0...+40 °C
Utilization category
Circuit breaker: A per IEC60947-2, Motor starter: AC-3 per IEC60947-4-1
Device construction
Built-in device fixed built-in technique
Mounting
DIN Rail (EN 60715)
Group mounting side by side
Up to 40 °C (104 °F)
Resistance to shock
25 G/11 ms per IEC 60068-2-27
Resistance to vibration
5 G/3 ... 150 Hz per IEC 60068-2-6
Degree of protection
Housing: IP20, Main terminals: IP10
Dessins
Dessins
3-Dimensional STEP model (STP) Télécharger (ZIP)
2-Dimensional Drawing (PDF) Télécharger (PDF)
Dessins
3-Dimensional STEP model (STP) Télécharger (ZIP)
2-Dimensional Drawing (PDF) Télécharger (PDF)
Documents
140mp-td002_-en-p Données techniques
140MP-TD002
Product Cutsheet Général
--
Link to Literature Library for Tech Data Général
140MP-TD001
Taper Ressource Publication
Données techniques 140mp-td002_-en-p 140MP-TD002
Général Product Cutsheet --
Général Link to Literature Library for Tech Data 140MP-TD001
Vous recherchez plus de documentation ?
Recherchez une documentation technique organisée pour ce produit dans le Centre de documentation technique ou recherchez dans notre bibliothèque documentaire complète.
Rechercher dans la bibliothèque littéraire
Certifications
IECEE Scheme UL Listed China CCC
  • IECEE Scheme
  • CE
  • UL Listed
  • Registro Italiano Navale
  • China CCC

Ce produit a été certifié conforme aux certifications mentionnées ci-dessus en date du 2025-07-19. Les produits vendus avant ou après cette date peuvent présenter des certifications différentes. Veuillez consulter l'étiquette du produit pour vérifier les certifications dont il dispose.

Accessoires
Articles par page:
1-1 de 1
Notes techniques
Vous recherchez plus de notes techniques ?
Trouvez des questions et des réponses des experts techniques de Rockwell Automation pour ce produit dans notre base de connaissances.
Rechercher dans la base de connaissances
Loading
Trouvez votre distributeur le plus proche
Contactez votre distributeur en {0}
Changer d'emplacement
EmailEmail
PhonePhone
Trouver un partenaire
Motor Protection Circuit Breaker
CloseClose
140MP-A3E-B25
Fermer
Imprimer
Chevron LeftChevron Left
Allen-Bradley 140MP-A3E-B25 product image
Chevron LeftChevron Left
Allen-Bradley 140MP-A3E-B25 product image
Allen-Bradley 140MP-A3E-B25 product image
Téléphone:
Appel
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Accueil Rockwell Automation
  2. Chevron LeftChevron Left Produits
Veuillez mettre à jour vos préférences en matière de cookies pour continuer.
Cette fonctionnalité nécessite des cookies pour améliorer votre expérience. Veuillez mettre à jour vos préférences pour autoriser ces cookies:
  • Cookies de réseaux sociaux
  • Cookies fonctionnels
  • Cookies de performances
  • Cookies marketing
  • Tous les cookies
Vous pouvez mettre à jour vos préférences à tout moment. Pour plus d'informations, veuillez consulter notre {0} politique de confidentialité
CloseClose