Loading

FactoryTalk® Production Centre Vulnerable to Apache ActiveMQ Vulnerability

Severity:
Critical
Advisory ID:
SD1668
Date de publication:
April 18, 2024
Date de la dernière mise à jour:
December 03, 2024
Revision Number:
1.0
Known Exploited Vulnerability (KEV):
Non
Corrected:
Non
Workaround:
Non
CVE IDs
CVE-2023-4664
Téléchargements
The following link(s) provide the security advisory in Vulnerability Exploitability Exchange format:
JSON
Résumé
FactoryTalk® Production Centre Vulnerable to Apache ActiveMQ Vulnerability

Published Date: April, 16, 2024

Last updated: April 16, 2024

Revision Number: 1.0

CVSS Score: 9.8 /10

AFFECTED PRODUCTS AND SOLUTION

Affected Product

First Known in Software Version

Corrected in Software Version

FactoryTalk® Production Centre

10.0

11.03.00

 

VULNERABILITY DETAILS

Rockwell Automation used version 3.1 of the CVSS scoring system to assess the following vulnerabilities. The security of our products is important to us as your chosen industrial automation supplier.  This anomaly was found internally during routine testing and is being reported based on our commitment to customer transparency and to improve their business or production environments.

 

CVE-2023-4664 IMPACT

Apache ActiveMQ, a component utilized in FactoryTalk Production Centre, is vulnerable to Remote Code Execution.  The vulnerability may allow a remote threat actor with network access to a broker to run arbitrary shell commands by manipulating serialized class types in the OpenWire protocol. This could cause the broker to instantiate any class on the classpath. 

CVSS Base Score: 9.8

CVSS Vector string: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CWE: 502 Deserialization of Untrusted Data

Known Exploited Vulnerability (KEV) database: Yes

Users can use Stakeholder-Specific Vulnerability Categorization to generate environment specific prioritization.

Mitigations and Workarounds

Users using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible. 

  • ·      Update to the version that fixes the issue as detailed in this article.
  • ·       Follow the security recommendations in PN1592 for FTPC.
  • ·       Implement Security Best Practices

 ADDITIONAL RESOURCES

·       JSON CVE-2023-46604

Rockwell Automation Home
Copyright ©2022 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Ûníîtééd Kíîngdòóm Chevron RightChevron Right
  2. Chevron LeftChevron Left Trust Center Chevron RightChevron Right
  3. Chevron LeftChevron Left Industrial Security Adv Chevron RightChevron Right
  4. Chevron LeftChevron Left Industrial Security Advisory Detail Chevron RightChevron Right
Veuillez mettre à jour vos préférences en matière de cookies pour continuer.
Cette fonctionnalité nécessite des cookies pour améliorer votre expérience. Veuillez mettre à jour vos préférences pour autoriser ces cookies:
  • Cookies de réseaux sociaux
  • Cookies fonctionnels
  • Cookies de performances
  • Cookies marketing
  • Tous les cookies
Vous pouvez mettre à jour vos préférences à tout moment. Pour plus d'informations, veuillez consulter notre {0} politique de confidentialité
CloseClose