Loading
Chevron UpChevron Up
Allen-Bradley 440R-GL2S2P product image
Allen-Bradley 440R-GL2S2P product image
Chevron DownChevron Down
Allen-Bradley 440R-GL2S2P product image
Allen Bradley
Más vendido

Guardmaster GLP Safety Relay

PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Catalog #: 440R-GL2S2P
Lifecycle status: Active
Allen-Bradley 440R-GL2S2P product image
Allen-Bradley 440R-GL2S2P product image
Allen-Bradley 440R-GL2S2P product image
Allen Bradley
PrintPrint
Print page
EmailEmail
Share page
Product RegistrationProduct Registration
Print QR code
Lifecycle status: Active
Add to BoM
  • Get Support
Technical Specifications
Drawings
Documents
Certifications
Accessories
Alternative Products
Technotes
Output 2 OSSD
SIL according to IEC 61508 2 None
Safety integrity level claim limit 2 None
Hardware fault tolerance 1 None
Safe failure fraction 98.95 %
PFH 7.19E-9 None
PFD 4.13E-09 None
Mode of operation High demand mode
With approval according to UL True
With approval for TUV True
Performance level according to EN ISO 13849-1 Level d
Mission time 20 year
Hours of operation 24 h
MTTFd 378 None
Days of operation 365 dbays
DC avg. (EN ISO 13849-1) 97.66 %
Category Up to 3
Performance level Up to d
T cycle 8/28.8 (h/s)
Rated operating frequency 4 khz
Evaluation inputs One- and two-channel
Type of electric connection Screw connection
Power consumption 2 W
Rated control supply voltage Us at DC 24 V
Wire size 0.2...2.5 mm² (24...14 AWG)
Number of outputs, safety related, undelayed, with contact 0 None
Number of outputs, safety related, delayed, with contact 0 None
Number of outputs, signalling function, undelayed, with contact 0 None
Number of outputs, signalling function, delayed, with contact 0 None
Number of outputs, signalling function, undelayed, semiconductors 1 None
Number of outputs, signalling function, delayed, semiconductors 0 None
Voltage type for actuating DC
Suitable for safety functions True
With detachable clamps True
With feedback circuit True
Surge auxillary output current duration, max 5 ms
Surge safety output current duration, max 5 ms
Continuous auxiliary output current 50 mA
Surge auxiliary output current 700 mA
Aggregate current of outputs per module, max 1.8 A
Continuous safety output current, max 0.5 A
Surge safety output current, max 1.5 A
Number of outputs, safety related, undelayed, semiconductor 2/4
Number of outputs, safety related, delayed, semiconductor 0/2
Other output SWS output
Operating voltage range 20.4
Configurable logic Logic setting 1 - cat 1 stop, logic IN off, Logic setting 2 - cat 1 stop with logic IN, Logic setting 3 - safe limited slow speed, logic IN off, Logic setting 4 - safe limited slow speed with logic IN, Logic setting 5...8 - guard locking with delayed unlo
Operating temperature -5 °C
Enclosure protection IP40 (NEMA 1)
Relative humidity 90%
Height 119.4 mm
Width 22.5 mm
Depth 113.6 mm
Vibration 10...55 Hz, 0.35 mm
Shock Shock proof, operating: 10 G, 16 ms
Function rotational speed monitoring True
Function standstill monitoring True
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability true
Quick Turnaround false
Dimension Height 3.2
Lead Time 30
Dimension Width 11.913
Dimension Length 12.395
Stock Status NON_STOCKED
Weight 0.184
Weight Unit KG
Dimension Unit CM
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
2-Dimensional Drawing (PDF) Download (PDF)
Product Drawing Drawing (DWG)
Product Drawing Drawing (DXF)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
2-Dimensional Drawing (PDF) Download (PDF)
Product Drawing Drawing (DWG)
Product Drawing Drawing (DXF)
Tipo Medio Publicación
General Product Cutsheet --
Installation Instructions 440r-in076_-mu-p 440R-IN076
User Manual 440r-um012_-en-p 440R-UM012
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
Korean KC
  • Korean KC

This product was certified with the above certifications as of 2025-01-26. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Ítems por página:
1-1 de 1
Ítems por página:
1-1 de 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Technical Specifications
Output 2 OSSD
SIL according to IEC 61508 2 None
Safety integrity level claim limit 2 None
Hardware fault tolerance 1 None
Safe failure fraction 98.95 %
PFH 7.19E-9 None
PFD 4.13E-09 None
Mode of operation High demand mode
With approval according to UL True
With approval for TUV True
Performance level according to EN ISO 13849-1 Level d
Mission time 20 year
Hours of operation 24 h
MTTFd 378 None
Days of operation 365 dbays
DC avg. (EN ISO 13849-1) 97.66 %
Category Up to 3
Performance level Up to d
T cycle 8/28.8 (h/s)
Rated operating frequency 4 khz
Evaluation inputs One- and two-channel
Type of electric connection Screw connection
Power consumption 2 W
Rated control supply voltage Us at DC 24 V
Wire size 0.2...2.5 mm² (24...14 AWG)
Number of outputs, safety related, undelayed, with contact 0 None
Number of outputs, safety related, delayed, with contact 0 None
Number of outputs, signalling function, undelayed, with contact 0 None
Number of outputs, signalling function, delayed, with contact 0 None
Number of outputs, signalling function, undelayed, semiconductors 1 None
Number of outputs, signalling function, delayed, semiconductors 0 None
Voltage type for actuating DC
Suitable for safety functions True
With detachable clamps True
With feedback circuit True
Surge auxillary output current duration, max 5 ms
Surge safety output current duration, max 5 ms
Continuous auxiliary output current 50 mA
Surge auxiliary output current 700 mA
Aggregate current of outputs per module, max 1.8 A
Continuous safety output current, max 0.5 A
Surge safety output current, max 1.5 A
Number of outputs, safety related, undelayed, semiconductor 2/4
Number of outputs, safety related, delayed, semiconductor 0/2
Other output SWS output
Operating voltage range 20.4
Configurable logic Logic setting 1 - cat 1 stop, logic IN off, Logic setting 2 - cat 1 stop with logic IN, Logic setting 3 - safe limited slow speed, logic IN off, Logic setting 4 - safe limited slow speed with logic IN, Logic setting 5...8 - guard locking with delayed unlo
Operating temperature -5 °C
Enclosure protection IP40 (NEMA 1)
Relative humidity 90%
Height 119.4 mm
Width 22.5 mm
Depth 113.6 mm
Vibration 10...55 Hz, 0.35 mm
Shock Shock proof, operating: 10 G, 16 ms
Function rotational speed monitoring True
Function standstill monitoring True
Sales Info
Repairable NOT_REPAIRABLE
Preferred Availability true
Quick Turnaround false
Dimension Height 3.2
Lead Time 30
Dimension Width 11.913
Dimension Length 12.395
Stock Status NON_STOCKED
Weight 0.184
Weight Unit KG
Dimension Unit CM
Drawings
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
2-Dimensional Drawing (PDF) Download (PDF)
Product Drawing Drawing (DWG)
Product Drawing Drawing (DXF)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
2-Dimensional Drawing (PDF) Download (PDF)
Product Drawing Drawing (DWG)
Product Drawing Drawing (DXF)
Documentos
Product Cutsheet General
--
440r-in076_-mu-p Installation Instructions
440R-IN076
440r-um012_-en-p User Manual
440R-UM012
Tipo Medio Publicación
General Product Cutsheet --
Installation Instructions 440r-in076_-mu-p 440R-IN076
User Manual 440r-um012_-en-p 440R-UM012
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Visit the Technical Documentation Center Chevron RightChevron Right Search the Literature Library Chevron RightChevron Right
Certificaciones
Korean KC
  • Korean KC

This product was certified with the above certifications as of 2025-01-26. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Accessories
Ítems por página:
1-1 de 1
Alternative Products
Ítems por página:
1-1 de 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase Chevron RightChevron Right
Loading
Find your nearest distributor
Change location
EmailEmail
PhonePhone
Find a partner Chevron RightChevron Right
Guardmaster GLP Safety Relay
CloseClose
440R-GL2S2P
Cerrar
Imprimir
Chevron LeftChevron Left
Allen-Bradley 440R-GL2S2P product image
Chevron RightChevron Right
Chevron LeftChevron Left
Allen-Bradley 440R-GL2S2P product image
Allen-Bradley 440R-GL2S2P product image
Chevron RightChevron Right
Teléfono:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Página principal de Rockwell Automation Chevron RightChevron Right
  2. Chevron LeftChevron Left Productos Chevron RightChevron Right
Actualice sus preferencias de cookies para continuar.
Esta función requiere cookies para mejorar su experiencia. Actualice sus preferencias para permitir estas cookies.:
  • Cookies de Redes Sociales
  • Cookies Funcionales
  • Cookies de Performance
  • Cookies de Marketing
  • Todas las cookies
Puede actualizar sus preferencias en cualquier momento. Para más información, vea nuestro {0} Política de Privacidad
CloseClose