Loading

FactoryTalk® Production Centre Vulnerable to Apache ActiveMQ Vulnerability

Severity:
Critical
Advisory ID:
SD1668
Published Date:
April 18, 2024
Last Updated:
December 03, 2024
Revision Number:
1.0
Known Exploited Vulnerability (KEV):
No
Corrected:
No
Workaround:
No
CVE IDs
CVE-2023-4664
Downloads
The following link(s) provide the security advisory in Vulnerability Exploitability Exchange format:
CVE-2024-46604
Summary
FactoryTalk® Production Centre Vulnerable to Apache ActiveMQ Vulnerability

Published Date: April, 16, 2024

Last updated: April 16, 2024

Revision Number: 1.0

CVSS Score: 9.8 /10

AFFECTED PRODUCTS AND SOLUTION

Affected Product

First Known in Software Version

Corrected in Software Version

FactoryTalk® Production Centre

10.0

11.03.00

 

VULNERABILITY DETAILS

Rockwell Automation used version 3.1 of the CVSS scoring system to assess the following vulnerabilities. The security of our products is important to us as your chosen industrial automation supplier.  This anomaly was found internally during routine testing and is being reported based on our commitment to customer transparency and to improve their business or production environments.

 

CVE-2023-4664 IMPACT

Apache ActiveMQ, a component utilized in FactoryTalk Production Centre, is vulnerable to Remote Code Execution.  The vulnerability may allow a remote threat actor with network access to a broker to run arbitrary shell commands by manipulating serialized class types in the OpenWire protocol. This could cause the broker to instantiate any class on the classpath. 

CVSS Base Score: 9.8

CVSS Vector string: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CWE: 502 Deserialization of Untrusted Data

Known Exploited Vulnerability (KEV) database: Yes

Users can use Stakeholder-Specific Vulnerability Categorization to generate environment specific prioritization.

Mitigations and Workarounds

Users using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible. 

  • ·      Update to the version that fixes the issue as detailed in this article.
  • ·       Follow the security recommendations in PN1592 for FTPC.
  • ·       Implement Security Best Practices

 ADDITIONAL RESOURCES

·       JSON CVE-2023-46604

Rockwell Automation Home
Copyright ©2022 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left United Kingdom Chevron RightChevron Right
  2. Chevron LeftChevron Left Trust Center Chevron RightChevron Right
  3. Chevron LeftChevron Left Industrial Security Adv Chevron RightChevron Right
  4. Chevron LeftChevron Left Industrial Security Advisory Detail Chevron RightChevron Right
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our Privacy Policy
CloseClose