Loading
  • alt text
  • alt text
alt text
alt text
1783-SAD4T0SBK9

Stratix 5950 Security Appliance

PrintPrint
Print
EmailEmail
Share
Product RegistrationProduct Registration
QR code
Allen-Bradley 1783-SAD4T0SBK9 product image
Allen-Bradley 1783-SAD4T0SBK9 product image
Allen-Bradley 1783-SAD4T0SBK9 product image
Lifecycle status: Discontinued
ErrorsErrors
Rockwell Automation announces that as of January 01, 2024, the Stratix 5950 Security Appliance will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
Discontinued Date: January 01, 2024 Replacement Category: Engineering Replacement
Product at a glance
Repair Options Available
Product Registration
Lifecycle status: Discontinued
ErrorsErrors
Rockwell Automation announces that as of January 01, 2024, the Stratix 5950 Security Appliance will be discontinued and no longer available for sale. Customers are encouraged to remove references to the affected product(s)
Discontinued Date: January 01, 2024 Replacement Category: Engineering Replacement
Product at a glance
Repair Options Available
Product Registration
Add to BoM
  • Register Product
  • Get Support
Technical Specifications
General
Mechanical
Electrical
Environmental
Drawings
Documents
Certifications
Accessories
Alternative Products
Technotes
Network Media
Male RJ45 to Male RJ45 Patchcord, Unshielded Twisted Pair, Teal TPE Cable, 1.9 m
# of Copper Ports Required
8 or less
# of Fiber Ports Required
None
Stratix Ethernet Family
Stratix 5950
Width
106.68 cm
Height
129.54 cm
Depth
159.26 cm
Screw torque, alarm terminal
0.56 nm
Screw torque, ground terminal
0.4 nm
Screw torque, power terminal
0.56 nm
Number of ports 10/100/1000 Mbps RJ45
2
Layer 2
False
Layer 3
False
Manageable
False
Pulse (digital) output
24 W
Power dissipation
24 W
Encryption
K9 encryption with limited VPN
Total number of ports
4
Wire size, alarm connection, solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire
0.8 mm²
Wire size, DC power connection, solid or stranded copper wire rated at 75 °C or greater
0.8 mm²
Wire size, ethernet connection
RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
Wire size, ground connection, solid or stranded copper wire
4 mm²
Mounting method
DIN rail (top hat rail)
Ethernet
True
Protection type
Alarm not rated
Wire insulation
Copper
Insulation stripping length
6.3±0.5
Alarm relay at 30V DC
1 A
Alarm relay at 48V DC
0.5 A
Current rating, user supply at 12 - 48V DC, maximum
2 A
Isolation voltage (continuous), basic insulation type, all ports to ground
60 V
Maximum insulation, DC power connection
1.2 mm
Number of ports 1GbE SFP
2
Wire strip length, alarm connection
6.3±0.5
Wire strip length, DC power connection
6.3±0.5
Wiring category on console ports
3
Wiring category on Ethernet ports
2
Wiring category on power and alarm ports
2
Housing base material
Open-style
Nominal position
T4
Delta connected motor power, max
T4
Temperature, surrounding air, maximum
60 °C
ESD immunity, IEC 61000-4-2, air discharges
8 kV
ESD immunity, IEC 61000-4-2, contact discharges
6 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz
1 kg/km
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz
10 kg/km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz
10 kg/km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)
15 g
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)
-40 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)
-40 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)
-40 °C
Emissions
IEC 61000-6-4
Ambient temperature, maximum
60 °C
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)
10 V
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on communication ports
±500
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on power ports
±2.5
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on signal ports
±1
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on power ports
±1
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on signal ports
±500
EFT/B immunity for IEC 61000-4-4 at 5 kHz on communication ports
±2
EFT/B immunity for IEC 61000-4-4 at 5 kHz on power ports
±2
EFT/B immunity for IEC 61000-4-4 at 5 kHz on signal ports
±2
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz
10 kg/km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing
5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on communication ports
±2
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on power ports
±2
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on signal ports
±1
Surge transient immunity, IEC 61000-4-5, line-line (DM) on power ports
±1
Surge transient immunity, IEC 61000-4-5, line-line (DM) on signal ports
±500
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)
-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)
-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)
-40 °C
Vibration, IEC 60068-2-6 (test Fc, operating) at 5 - 150 Hz
1 g
Voltage variation IEC 61000-4-29, dips for 10 ms and 5 s on DC supply ports
100 %
Voltage variation IEC 61000-4-29, dips for 10 ms on DC supply ports
30 %
Voltage variation IEC 61000-4-29, dips for 100 ms and 1 s on DC supply ports
60 %
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Type Resource Publication
Application Techniques APPLICATION_TECHNIQUES_enet-at007_-en-p ENET-AT007
Application Techniques APPLICATION_TECHNIQUES_enet-at006_-en-p ENET-AT006
General Product Registration Link --
General Product Cutsheet --
Installation Instructions 1783-in016_-en-p 1783-IN016
Profile PROFILE_migrat-pp043_-en-p MIGRAT-PP043
Reference Manual REFERENCE_MANUAL_enet-rm002_-en-p ENET-RM002
User Manual 1783-um010_-en-p 1783-UM010
User Manual USER_MANUAL_1783-um007_-en-p 1783-UM007
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
China CCC UL Listed
  • China CCC
  • UL Listed

This product was certified with the above certifications as of 2025-04-15. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Items Per Page:
1-1 of 1
Items Per Page:
1-1 of 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
Network Media
Male RJ45 to Male RJ45 Patchcord, Unshielded Twisted Pair, Teal TPE Cable, 1.9 m
# of Copper Ports Required
8 or less
# of Fiber Ports Required
None
Stratix Ethernet Family
Stratix 5950
Width
106.68 cm
Height
129.54 cm
Depth
159.26 cm
Screw torque, alarm terminal
0.56 nm
Screw torque, ground terminal
0.4 nm
Screw torque, power terminal
0.56 nm
Number of ports 10/100/1000 Mbps RJ45
2
Layer 2
False
Layer 3
False
Manageable
False
Pulse (digital) output
24 W
Power dissipation
24 W
Encryption
K9 encryption with limited VPN
Total number of ports
4
Wire size, alarm connection, solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire
0.8 mm²
Wire size, DC power connection, solid or stranded copper wire rated at 75 °C or greater
0.8 mm²
Wire size, ethernet connection
RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
Wire size, ground connection, solid or stranded copper wire
4 mm²
Mounting method
DIN rail (top hat rail)
Ethernet
True
Protection type
Alarm not rated
Wire insulation
Copper
Insulation stripping length
6.3±0.5
Alarm relay at 30V DC
1 A
Alarm relay at 48V DC
0.5 A
Current rating, user supply at 12 - 48V DC, maximum
2 A
Isolation voltage (continuous), basic insulation type, all ports to ground
60 V
Maximum insulation, DC power connection
1.2 mm
Number of ports 1GbE SFP
2
Wire strip length, alarm connection
6.3±0.5
Wire strip length, DC power connection
6.3±0.5
Wiring category on console ports
3
Wiring category on Ethernet ports
2
Wiring category on power and alarm ports
2
Housing base material
Open-style
Nominal position
T4
Delta connected motor power, max
T4
Temperature, surrounding air, maximum
60 °C
ESD immunity, IEC 61000-4-2, air discharges
8 kV
ESD immunity, IEC 61000-4-2, contact discharges
6 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz
1 kg/km
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz
10 kg/km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz
10 kg/km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)
15 g
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)
-40 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)
-40 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)
-40 °C
Emissions
IEC 61000-6-4
Ambient temperature, maximum
60 °C
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)
10 V
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on communication ports
±500
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on power ports
±2.5
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on signal ports
±1
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on power ports
±1
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on signal ports
±500
EFT/B immunity for IEC 61000-4-4 at 5 kHz on communication ports
±2
EFT/B immunity for IEC 61000-4-4 at 5 kHz on power ports
±2
EFT/B immunity for IEC 61000-4-4 at 5 kHz on signal ports
±2
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz
10 kg/km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing
5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on communication ports
±2
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on power ports
±2
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on signal ports
±1
Surge transient immunity, IEC 61000-4-5, line-line (DM) on power ports
±1
Surge transient immunity, IEC 61000-4-5, line-line (DM) on signal ports
±500
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)
-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)
-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)
-40 °C
Vibration, IEC 60068-2-6 (test Fc, operating) at 5 - 150 Hz
1 g
Voltage variation IEC 61000-4-29, dips for 10 ms and 5 s on DC supply ports
100 %
Voltage variation IEC 61000-4-29, dips for 10 ms on DC supply ports
30 %
Voltage variation IEC 61000-4-29, dips for 100 ms and 1 s on DC supply ports
60 %
Drawings
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Drawings
3-Dimensional STEP model (STP) Download (ZIP)
Documents
APPLICATION_TECHNIQUES_enet-at007_-en-p Application Techniques
ENET-AT007
APPLICATION_TECHNIQUES_enet-at006_-en-p Application Techniques
ENET-AT006
Product Registration Link General
--
Product Cutsheet General
--
1783-in016_-en-p Installation Instructions
1783-IN016
PROFILE_migrat-pp043_-en-p Profile
MIGRAT-PP043
REFERENCE_MANUAL_enet-rm002_-en-p Reference Manual
ENET-RM002
1783-um010_-en-p User Manual
1783-UM010
USER_MANUAL_1783-um007_-en-p User Manual
1783-UM007
Type Resource Publication
Application Techniques APPLICATION_TECHNIQUES_enet-at007_-en-p ENET-AT007
Application Techniques APPLICATION_TECHNIQUES_enet-at006_-en-p ENET-AT006
General Product Registration Link --
General Product Cutsheet --
Installation Instructions 1783-in016_-en-p 1783-IN016
Profile PROFILE_migrat-pp043_-en-p MIGRAT-PP043
Reference Manual REFERENCE_MANUAL_enet-rm002_-en-p ENET-RM002
User Manual 1783-um010_-en-p 1783-UM010
User Manual USER_MANUAL_1783-um007_-en-p 1783-UM007
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Certifications
China CCC UL Listed
  • China CCC
  • UL Listed

This product was certified with the above certifications as of 2025-04-15. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Accessories
Items Per Page:
1-1 of 1
Alternative Products
Items Per Page:
1-1 of 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Loading
Find your nearest distributor
Contact your distributor in {0}
Change location
EmailEmail
PhonePhone
Find a partner
Stratix 5950 Security Appliance
CloseClose
1783-SAD4T0SBK9
Close
Print
Chevron LeftChevron Left
Allen-Bradley 1783-SAD4T0SBK9 product image
Chevron LeftChevron Left
Allen-Bradley 1783-SAD4T0SBK9 product image
Allen-Bradley 1783-SAD4T0SBK9 product image
Phone:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
Sign in to your Rockwell Automation account to submit a repair documentation request.
Sign In
Request repair documentation
All fields with * are required for processing your request.
This field is required
This field is required
This field is required
This field is required
This field is required
Documentation of liability insurance is required for anyone who is requesting documentation for product repairs.
UploadUpload
Please upload documentation of liability insurance.*
1 file selected
CloseClose
File size is too large. Must be less than 5 MB.
Accepted file types: zip, pdf; Maximum size: 5 MB.
Right to Repair Terms and Conditions
Rockwell Automation is making, parts, and service documentation available at your request in compliance with applicable right to repair laws and regulations. By signing below, you are agreeing to the following terms and conditions of your purchase of Rockwell Automation genuine repair parts for repair of a Rockwell Automation product. As used below, “Self Service Repair Parts” means genuine Rockwell Automation parts (components of Rockwell Automation products) purchased from Rockwell Automation for installation in a Rockwell Automation product as part of a Self Service Repair. Self Service Repair Parts may be new or previously used genuine Rockwell Automation parts that have been tested and passed Rockwell Automation functional requirements. “Self Service Repair Tools” means equipment and related materials purchased for the purpose of performing repairs.
Your request has been successfully submitted.
Please allow up to 5 business days to receive a response to your inquiry.
  1. Chevron LeftChevron Left Rockwell Automation Home
  2. Chevron LeftChevron Left Products
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose