PN1502 | OSIsoft PI System Vulnerabilities Affect Multiple Rockwell Automation Software Products

Severity:
High,
Medium
Advisory ID:
PN1502
Published Date:
May 12, 2020
Last Updated:
May 12, 2020
Revision Number:
2.0
Known Exploited Vulnerability (KEV):
No
Corrected:
No
Workaround:
No
CVE IDs
CVE-2020-10608,
CVE-2020-10606,
CVE-2020-10645,
CVE-2020-10600,
CVE-2020-10610
Summary
OSIsoft PI System Vulnerabilities Affect Multiple Rockwell Automation Software Products

Revision History
Revision Number
2.0
Revision History
Version 2.0 - October, 13, 2020. Updated risk mitigations and recommended user actions.
Version 1.0 - May 12, 2020.  Initial Release.

Executive Summary

OSIsoft reported five vulnerabilities in PI System, a real-time data collection and visualization software, to Rockwell Automation. PI System software is used in multiple Rockwell Automation® software products. These vulnerabilities if successfully exploited, may result in privilege escalation, information disclosure or a denial-of-service condition.

Not every PI System vulnerability applies to each impacted product. Please see the table under Affected Products for a full list of the affected Rockwell Automation products and the corresponding PI System vulnerability.

Customers using affected products are encouraged to evaluate their own systems and apply the appropriate risk mitigations from those listed below. Additional details relating to the discovered vulnerabilities and recommended countermeasures, are provided herein.

Affected Products

Product CVE-2020-10610 CVE-2020-10608 CVE-2020-10606 CVE-2020-10600 CVE-2020-10645
FactoryTalk® View SE software version 11.00.00 and earlier X X X
FactoryTalk® VantagePoint® software version 8.10.00 and earlier X X X
FactoryTalk Historian - ThingWorx Connector software version 3.00.00 X X X
FactoryTalk Historian SE software version 6.00.00 and earlier X X X X
PlantPAx® DCS software (including Virtual Templates) version 4.60.00 and earlier X X X
FactoryTalk ProcessBook software version 3.60.00 and earlier X X X X
FactoryTalk Datalink software version 5.30.00 and earlier X X X
FactoryTalk Historian SE to Historian SE (SE2SE) Interface software version 3.08.07 and earlier X X X
FactoryTalk Historian SE Interface for Universal File Loader software version 3.01.02 and earlier X X X
FactoryTalk Historian SE Interface for ODBC (RDBMS) software version 3.20.06 and earlier X X X
FactoryTalk Historian Batch Interface software version 1.00.20 and earlier X X X
FactoryTalk Historian Event Frames Generator (PE EFGen) software version 4.00.25 and earlier X X X
FactoryTalk Historian SE Advance Server software version 6.00.00 and earlier X X X
FactoryTalk Historian SE third-party OLEDB Connectivity software version 4.00.00 and earlier X X X
FactoryTalk Historian SE third-party OPC Connectivity software version 4.00.00 and earlier X X X

Vulnerability Details

OSISoft provided the vulnerability details in their security advisory.

CVE-2020-10610: Local Privilege Escalation via Uncontrolled Search Path Element
A local attacker can modify a search path and plant a binary to exploit the affected PI System software and take control of the local computer at system level privileges, resulting in unauthorized information disclosure, deletion or modification.

CVSS v3 Base Score: 7.8/10 (HIGH)
CVSS Vector String: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.c

CVE-2020-10608: Local Privilege Escalation via Improper Verification of Cryptographic Signature
A local attacker can plant a binary and bypass a code integrity check for loading PI System libraries. Exploitation can target another local user of the software to escalate privilege, resulting in unauthorized information disclosure, deletion or modification.

CVSS v3 Base Score: 7.8/10 (HIGH)
CVSS Vector String: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.

CVE-2020-10606: Local Privilege Escalation via Incorrect Default Permissions
A local attacker can exploit incorrect permissions set by affected PI System software. Exploitation can result in unauthorized disclosure, deletion, or modification if the local computer also processes PI System data from other users such as a shared workstation or terminal server deployment.

CVSS v3 Base Score: 7.8/10 (HIGH)
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.

CVE-2020-10600: Null Pointer Dereference may cause Denial-conditions
A remote, authenticated attacker could crash PI Archive Subsystem when the subsystem is working under memory pressure. This can result in blocking queries to PI Data Archive and may cause denial-of-service conditions.

CVSS v3 Base Score: 5.9/10 (MEDIUM)
CVSS Vector String: CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:H.

CVE-2020-10645: Use of Out-of-range Pointer Offset may lead to Remote Code Execution
A remote, authenticated attacker could embed malicious content in the display file of the impacted software product. When opened by an affected version, the attacker could read, write and execute code on the computer with the impacted software in the context of the current user.

CVSS v3 Base Score: 8.0/10 (HIGH)*
CVSS Vector String: CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H

* Note: OSIsoft calculated the Temporal CVSS metrics for this vulnerability, which brings the score to a 6.4/10 (MEDIUM)

Risk Mitigation & User Action

Currently, Rockwell Automation is working to address these vulnerabilities and will continue to provide updates and user guidance as these fixes become available. Please subscribe to security updates to this advisory and the Industrial Security Index (Knowledgebase PN1354) to stay notified.

Customers currently using any of the affected software are encouraged to take the following actions:

v2.0 - Update:

Product CVE Identifiers Suggested Action
FactoryTalk® View SE software CVE-2020-10606
CVE-2020-10608
CVE-2020-10610
Download v12.00.00 or later.
FactoryTalk Historian SE CVE-2020-10600
CVE-2020-10606
CVE-2020-10608
CVE-2020-10610
Download v7.00.00 or later.
PlantPAx® DCS software (including Virtual Templates) CVE-2020-10606
CVE-2020-10608
CVE-2020-10610
Download v5.00 or later.
FactoryTalk ProcessBook software CVE-2020-10606
CVE-2020-10608
CVE-2020-10610
CVE-2020-10645
Download v3.70.01 or later.
FactoryTalk Datalink software CVE-2020-10606
CVE-2020-10608
CVE-2020-10610
Download v5.50.02 or later.
FactoryTalk Historian SE Interface for Universal File Loader software CVE-2020-10606
CVE-2020-10608
CVE-2020-10610
Download v3.60.07 or later.
FactoryTalk Historian SE Interface for ODBC (RDBMS) software CVE-2020-10606
CVE-2020-10608
CVE-2020-10610
Download v3.24.05 or later.
FactoryTalk Historian Event Frames Generator (PE EFGen) software CVE-2020-10606
CVE-2020-10608
CVE-2020-10610
Download v4.00.40 or later.
FactoryTalk Historian SE Advance Server software CVE-2020-10606
CVE-2020-10608
CVE-2020-10610
Download v7.00.00 or later.
FactoryTalk Historian SE third-party OLEDB Connectivity software CVE-2020-10606
CVE-2020-10608
CVE-2020-10610
Download v7.00.00 or later.
FactoryTalk Historian SE third-party OPC Connectivity software CVE-2020-10606
CVE-2020-10608
CVE-2020-10610
Download v7.00.00 or later.

v1.0 - Initial Release:
Customers currently using any of the affected software that is not listed in the table above are encouraged to take the following actions:

Vulnerability Identifier Suggested Actions
CVE-2020-10610
  • Work with your IT administrator to manage permissions on HKLMSoftwarePISystem and HKLMSoftwareWOW6432NodePISystem registry keys to block a high impact exploit path.
  • Monitor the above keys and the following folder: ProgramDataPISystem for any unauthorized changes
  • See Knowledgebase ID QA59280 for details on setting registry permissions.
  • See Knowledgebase ID QA59281 for details on monitoring the registry.
CVE-2020-10608
  • Restrict network connections from PI client workstations to trusted AF servers (TCP port 5457)
CVE-2020-10606
  • Evaluate and disable unused PI Buffering services from PI client workstations (PI Buffer Subsystem, PI Buffer Server)
  • By default, buffering is not configured. If buffering is configured, the preferred method of authentication is to use Windows Authentication for the connection from the Buffer to the Historian.
  • See Knowledgebase ID QA59282 to check whether PI Buffering is enabled.
CVE-2020-10600
  • Limit console and remote desktop logon access to authorized administrators for normally unattended PI System servers and interface nodes.
CVE-2020-10645
  • Delete lfmngu.dll from %PIHOME%Procbook directory (typically C:Program Files (x86)Rockwell SoftwareFactoryTalk HistorianPIPCProcbook or C:Program Files (x86)PIPCProcbook).
  • The third-party library is not needed for supported PI ProcessBook features.
  • See Knowledgebase Document ID QA56969 for other possible default installation paths.

General Security Guidelines

  • Run all software as user, not as an administrator, to minimize the impact of malicious code on the infected system.
  • (CVE-2020-10610 & CVE-2020-10608) Use of Microsoft® AppLocker or other similar whitelisting application can help mitigate risk. Information on using AppLocker with Rockwell Automation products is available at Knowledgebase Article ID 546989.
  • Ensure that the least-privilege user principle is followed, and user/service account access to shared resources (such as a database) is only granted with a minimum amount of rights as needed.
  • Minimize network exposure for all control system devices and/or systems and ensure that they are not accessible from the Internet. For further information about the risks of unprotected Internet accessible control systems, please see Knowledgebase Article ID 494865.
  • Locate control system networks and devices behind firewalls and isolate them from the business network.

For further information on the Vulnerability Handling Process for Rockwell Automation, please refer to our Product Security Incident Response FAQ document.

See our Industrial Network Architectures Page for comprehensive information about implementing validated architectures designed to complement security solutions.

Refer to the Network Services Overview Page for information on network and security services for Rockwell Automation to enable assessment, design, implementation and management of validated, secure network architectures.

We also recommend that concerned customers continue to monitor this advisory by subscribing to updates on the Security Advisory Index for Rockwell Automation at 54102 - Industrial Security Advisory Index.

Rockwell Automation remains committed to making security enhancements to our systems in the future. For more information and for assistance with assessing the state of security of your existing control system, including improving your system-level security when using Rockwell Automation and other vendor controls products, you can visit the Rockwell Automation Security Solutions website.

Requests for additional information can be sent to the RASecure Inbox (rasecure@ra.rockwell.com).
Please direct all media inquiries to Kolve Byrd (kabyrd@ra.rockwell.com).

Additional Links

  • 54102 - Industrial Security Advisory Index
  • Industrial Firewalls within a CPwE Architecture
  • Deploying Industrial Firewalls within a CPwE Architecture Design and Implementation Guide
  • ICS Advisory (ICSA-20-133-02)

Rockwell Automation Home
Copyright ©2022 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left United Kingdom Chevron RightChevron Right
  2. Chevron LeftChevron Left Trust Center Chevron RightChevron Right
  3. Chevron LeftChevron Left Industrial Security Adv Chevron RightChevron Right
  4. Chevron LeftChevron Left Industrial Security Advisory Detail Chevron RightChevron Right
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose