Technical Specifications
General
Electrical
Construction
Environmental
Certification
Tachometer input
Inputs
Measurements
Mechanical
Voted Alarms
Signal Conditioning
Module
Indicators
Power
Real-Time Measurement
Alarms
Relays
Data Buffers
Data
Outputs
Communication
Configuration
Documents
Downloads
Certifications
Alternative Products
Technotes
Output
2
Transducer Power
IEPE Accel, ECP's, Volts
Number of sensor inputs for IEPE sensors
2
Number of indicator outputs
7
Type of electric connection
Screw connection
Voltage type of supply voltage
DC
Ethernet
False
Suitable for bus connection
True
Model
Basic device
Number of rotational speed inputs
1
Type of fastening
Direct mounting
Modular expandable
True
Enclosure type rating
None (open-style)
Surrounding air temperature, max
65 °C
Operating temperature
-20 °C
Emissions
Class A
Vibration
5 G @ 10...500 Hz
Shock
Opsal: 15 G
EFT/B immunity
±3kV @ 5kHz on power ports, ±3kV @ 5kH on signal ports, ±3kV @ 5kHz on DeviceNet ports
Surge transient immunity
±1 kV line-line (DM) and ±2 kV line-earth (CM) on power and relay ports, ±2 kV line-earth (CM) on shielded signal ports, ±2 kV line-earth (CM) on DeviceNet ports
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Storage temperature
-40 °C
Relative humidity
5...95% noncondensing
ESD immunity
6 kV contact discharges, 8 kV air discharges
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
North American temperature code
T5
With approval according to UL
True
IEC temperature code
T4
Input impedance
>120 kΩ
Rate of change of speed, max
500 Hz/s
Pulses per revolution
0 (tach off)…50,000
Range
1...1,200,000 rpm, 0.0167…20,000 Hz
One tachometer input
±25V (50V max peak-to-peak), 1...50,000 events/revolution
Voltage ranges
-20…0V DC, -10...10V DC, 0…20V DC
Sensitivity
Up to 15% from nom
Two dynamic channel inputs
Eddy current transducer signals, Accelerom signals, Voltage signals from any dynamic measurement sensor, such as velocity or pressure transducer
Transducer power
Constant voltage: 24V DC, -24V DC @ 40mA, Constant current 4.5 mA ± 30% / -20% from 24V DC (IEPE), None (voltage input), Tachom can be powered, constant voltage, or configured as voltage input
Type
FFT and time waveform, Asynchronous or synchronous
FFT derived
FFT bands, Four bands per channel, Defined in frequency or order domain, Overall or max peak in band, Orders, Magnitude: 1x, 2x, 3x, Phase: 1x, 2x, Not 1x, Sum harmonics
Weight
Module: 0.172 kg (0.38 lb), Terminal base: 0.172 kg (0.38 lb)
Height
97 mm
Width
94 mm
Depth
94 mm
Failsafe
Normally energized (fail-safe), Normally de-energized (non-failsafe)
Latching
Latching, non-latching
Number
Sixteen alarm and danger pairs
Resolution
A/D conversion: 24 bit, Dynamic range: 80 dbfs (0.01% fs), 90 dbfs, typical
Sampling mode
Selectable per channel, Dynamic Measurements, Asynchronous, FMAX: 1 Hz…20 kHz, Synchronous, Order range: 4…200, FMAX: 10 Hz…5000 Hz, Measured: orders x speed (Hz), Spike Energy, Static Measurements, Eccentricity, Peak-to-Peak Eccentricity, Thrust, Normal
Integration
None, single or double
FFT lines
100, 200, 400, 800, 1600
Units
G, ips, mm/s, mils, µm, PSI, mbar, volt
Low pass analog filter
Applied to integrated acceleration measurements, -3 dB corner: 5 kHz, roll off: -18 dB/octave
High pass analog filters
-3 dB corners: 0.2, 1, 5, 10, 40 Hz, Roll off: -30 dB/octave for the 0.2 Hz filter, otherwise 24 dB/octave
Band pass digital filter
Independently configured per channel, Frequency, min 25...1000 Hz, Frequency, max 100…5500 Hz, Roll off: -60 dB/octave
Low pass digital filter
Independently configured per channel, Optional Overall LP Filter, 100...20000 Hz, Spike Energy, Spectra FMAX: 10...5000 Hz, Roll Off: -24 dB/octave
Tracking digital filter
Independently configured per channel, Tracked speed multiple: 0.1...20.0 times the measured (tachom) rpm, Constant Q: 1...200, Constant bandwidth: 0.1...25 Hz, Roll off: -36 dB/octave, Typical
Wiring category
2 - on signal ports, 1 - on power and relay ports, 2 - on DeviceNet ports, 3 - on serial ports
Power dissipation, max
8.7 W
Power supply
24V DC @ 350mA, Requires Class 2/SELV/PELV power supply
Status indicator
Module, Network, Channel 1, Channel 2, Tachom, Setpoint multiplier, Virtual relay
Isolation voltage
50V (continuous), basic insulation type between uninsulated live parts and the enclosure with the relay contacts open and closed, Type tested at 707V DC @ 60s between uninsulated live parts and the enclosure with the relay contacts open and closed, Typ
Real time
Overall, RMS, Peak (true or calculated), Peak-to-peak (true or calculated), gSE, Optional low pass filter, -3 dB corner: 200 Hz...20 kHz, Roll off: -24 dB/octave, Gap (or transducer bias voltage), Speed, SMAX magnitude, SMAX phase, Band pass filter value,
Alarm parameters
Any measured param
Hysteresis
User configurable in software
Operators
Greater than, Less than, Inside range, Outside range
Startup inhibit/setpoint multiplication
Period: 0...1092 min, adjustable in 0.1 min increments, Inhibit/multiplication function, Multiply by N (0...10, 0 = Disarm)
Speed inhibit
A speed range can be specified for each alarm. When applied, the alarm is disabled when speed is outside of the defined range.
Time delay
0…25.5 s, adjustable in 100 ms increments
Expected life (min operations)
Mechanical: 2x10^7, Electrical @ 20 cpm, 1.5A @ 24V DC: 10^5
Logic
Single or paired AND or OR logic that is applied to any alarm
Activation on
Alarm Status: Normal, Alert, Danger, Disarm, Transducer fault, Module fault, Tacho fault
Rating (resistive)
Capacity, nominal: 1.5A @ 24V DC, Capacity, min 100 µA @ 100 mV DC, Power, max 41.4 W, Voltage, max 27.6V DC, Current, max 1.5 A
Peak speed capture
The XM-124 retains the value of the highest speed that is observed since module power was cycled or the peak speed value was manually reset
Reset
Local reset switch on top of module, Remote reset switch that is wired to terminal base, Digital reset command via serial or DeviceNet interface
Spectra or waveform
Saved upon same trigger as delta time buffer
Delta time buffer
Number of records: 2048, Delta time interval: 1…3600 s, Trigger mode: Relay is activated or trigger event (such as DeviceNet command from a controller or host)
Delta rpm buffer
Number of records: 512, Delta speed interval: 1…3600 rpm, Trigger mode: Startup collects data in increasing rpm direction only, coast-down collects data in both increasing and decreasing directions, The data that is collected in the buffer is user configu
Accuracy, min
±1% of full scale range for the channel, ±1% of alarm setpoint for speed
Complex data
Spectra (synchronous or asynchronous), Waveform (synchronous or asynchronous), Simultaneous waveforms (synchronous), gSE Spectra
Buffered outputs
One active buffer per dynamic channel, One resistive buffer for tachom
4...20 mA outputs
Each output is independently progmed to represent any measured param, from either channel, Two isolated outputs, 300 Ω max load
Serial
RS-232 via mini-connector or terminal base unit, Communication rate that is fixed at 19.2 Kbps, Local configuration via the Serial Configuration Utility
DeviceNet network
Standard DeviceNet protocol for all functions (not power-module power is provided independently), Available EDS file supports most DeviceNet compliant systems, Communication rate that is set automatically by bus master to 125 Kbps, 250 Kbps, or 500 Kbps,
Nonvolatile configuration
A copy of the module configuration is retained in nonvolatile memory from which the configuration is loaded upon powerup, The configuration that is stored in nonvolatile memory can be deleted only by a module-reset,command that is sent via a serial interf
Type Resource Publication
General Product Cutsheet --
Technical Data 1440-td001_-en-p 1440-TD001
User Manual 1440-um001_-en-p 1440-UM001
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Available Downloads
  • Firmware for 1440-SDM02-01RA v8.000
See All Downloads
China CCC
  • China CCC
  • MOROCCO DOC

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Items Per Page:
1-1 of 1
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Technical Specifications
Output
2
Transducer Power
IEPE Accel, ECP's, Volts
Number of sensor inputs for IEPE sensors
2
Number of indicator outputs
7
Type of electric connection
Screw connection
Voltage type of supply voltage
DC
Ethernet
False
Suitable for bus connection
True
Model
Basic device
Number of rotational speed inputs
1
Type of fastening
Direct mounting
Modular expandable
True
Enclosure type rating
None (open-style)
Surrounding air temperature, max
65 °C
Operating temperature
-20 °C
Emissions
Class A
Vibration
5 G @ 10...500 Hz
Shock
Opsal: 15 G
EFT/B immunity
±3kV @ 5kHz on power ports, ±3kV @ 5kH on signal ports, ±3kV @ 5kHz on DeviceNet ports
Surge transient immunity
±1 kV line-line (DM) and ±2 kV line-earth (CM) on power and relay ports, ±2 kV line-earth (CM) on shielded signal ports, ±2 kV line-earth (CM) on DeviceNet ports
Radiated RF immunity
10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Storage temperature
-40 °C
Relative humidity
5...95% noncondensing
ESD immunity
6 kV contact discharges, 8 kV air discharges
Conducted RF immunity
10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
North American temperature code
T5
With approval according to UL
True
IEC temperature code
T4
Input impedance
>120 kΩ
Rate of change of speed, max
500 Hz/s
Pulses per revolution
0 (tach off)…50,000
Range
1...1,200,000 rpm, 0.0167…20,000 Hz
One tachometer input
±25V (50V max peak-to-peak), 1...50,000 events/revolution
Voltage ranges
-20…0V DC, -10...10V DC, 0…20V DC
Sensitivity
Up to 15% from nom
Two dynamic channel inputs
Eddy current transducer signals, Accelerom signals, Voltage signals from any dynamic measurement sensor, such as velocity or pressure transducer
Transducer power
Constant voltage: 24V DC, -24V DC @ 40mA, Constant current 4.5 mA ± 30% / -20% from 24V DC (IEPE), None (voltage input), Tachom can be powered, constant voltage, or configured as voltage input
Type
FFT and time waveform, Asynchronous or synchronous
FFT derived
FFT bands, Four bands per channel, Defined in frequency or order domain, Overall or max peak in band, Orders, Magnitude: 1x, 2x, 3x, Phase: 1x, 2x, Not 1x, Sum harmonics
Weight
Module: 0.172 kg (0.38 lb), Terminal base: 0.172 kg (0.38 lb)
Height
97 mm
Width
94 mm
Depth
94 mm
Failsafe
Normally energized (fail-safe), Normally de-energized (non-failsafe)
Latching
Latching, non-latching
Number
Sixteen alarm and danger pairs
Resolution
A/D conversion: 24 bit, Dynamic range: 80 dbfs (0.01% fs), 90 dbfs, typical
Sampling mode
Selectable per channel, Dynamic Measurements, Asynchronous, FMAX: 1 Hz…20 kHz, Synchronous, Order range: 4…200, FMAX: 10 Hz…5000 Hz, Measured: orders x speed (Hz), Spike Energy, Static Measurements, Eccentricity, Peak-to-Peak Eccentricity, Thrust, Normal
Integration
None, single or double
FFT lines
100, 200, 400, 800, 1600
Units
G, ips, mm/s, mils, µm, PSI, mbar, volt
Low pass analog filter
Applied to integrated acceleration measurements, -3 dB corner: 5 kHz, roll off: -18 dB/octave
High pass analog filters
-3 dB corners: 0.2, 1, 5, 10, 40 Hz, Roll off: -30 dB/octave for the 0.2 Hz filter, otherwise 24 dB/octave
Band pass digital filter
Independently configured per channel, Frequency, min 25...1000 Hz, Frequency, max 100…5500 Hz, Roll off: -60 dB/octave
Low pass digital filter
Independently configured per channel, Optional Overall LP Filter, 100...20000 Hz, Spike Energy, Spectra FMAX: 10...5000 Hz, Roll Off: -24 dB/octave
Tracking digital filter
Independently configured per channel, Tracked speed multiple: 0.1...20.0 times the measured (tachom) rpm, Constant Q: 1...200, Constant bandwidth: 0.1...25 Hz, Roll off: -36 dB/octave, Typical
Wiring category
2 - on signal ports, 1 - on power and relay ports, 2 - on DeviceNet ports, 3 - on serial ports
Power dissipation, max
8.7 W
Power supply
24V DC @ 350mA, Requires Class 2/SELV/PELV power supply
Status indicator
Module, Network, Channel 1, Channel 2, Tachom, Setpoint multiplier, Virtual relay
Isolation voltage
50V (continuous), basic insulation type between uninsulated live parts and the enclosure with the relay contacts open and closed, Type tested at 707V DC @ 60s between uninsulated live parts and the enclosure with the relay contacts open and closed, Typ
Real time
Overall, RMS, Peak (true or calculated), Peak-to-peak (true or calculated), gSE, Optional low pass filter, -3 dB corner: 200 Hz...20 kHz, Roll off: -24 dB/octave, Gap (or transducer bias voltage), Speed, SMAX magnitude, SMAX phase, Band pass filter value,
Alarm parameters
Any measured param
Hysteresis
User configurable in software
Operators
Greater than, Less than, Inside range, Outside range
Startup inhibit/setpoint multiplication
Period: 0...1092 min, adjustable in 0.1 min increments, Inhibit/multiplication function, Multiply by N (0...10, 0 = Disarm)
Speed inhibit
A speed range can be specified for each alarm. When applied, the alarm is disabled when speed is outside of the defined range.
Time delay
0…25.5 s, adjustable in 100 ms increments
Expected life (min operations)
Mechanical: 2x10^7, Electrical @ 20 cpm, 1.5A @ 24V DC: 10^5
Logic
Single or paired AND or OR logic that is applied to any alarm
Activation on
Alarm Status: Normal, Alert, Danger, Disarm, Transducer fault, Module fault, Tacho fault
Rating (resistive)
Capacity, nominal: 1.5A @ 24V DC, Capacity, min 100 µA @ 100 mV DC, Power, max 41.4 W, Voltage, max 27.6V DC, Current, max 1.5 A
Peak speed capture
The XM-124 retains the value of the highest speed that is observed since module power was cycled or the peak speed value was manually reset
Reset
Local reset switch on top of module, Remote reset switch that is wired to terminal base, Digital reset command via serial or DeviceNet interface
Spectra or waveform
Saved upon same trigger as delta time buffer
Delta time buffer
Number of records: 2048, Delta time interval: 1…3600 s, Trigger mode: Relay is activated or trigger event (such as DeviceNet command from a controller or host)
Delta rpm buffer
Number of records: 512, Delta speed interval: 1…3600 rpm, Trigger mode: Startup collects data in increasing rpm direction only, coast-down collects data in both increasing and decreasing directions, The data that is collected in the buffer is user configu
Accuracy, min
±1% of full scale range for the channel, ±1% of alarm setpoint for speed
Complex data
Spectra (synchronous or asynchronous), Waveform (synchronous or asynchronous), Simultaneous waveforms (synchronous), gSE Spectra
Buffered outputs
One active buffer per dynamic channel, One resistive buffer for tachom
4...20 mA outputs
Each output is independently progmed to represent any measured param, from either channel, Two isolated outputs, 300 Ω max load
Serial
RS-232 via mini-connector or terminal base unit, Communication rate that is fixed at 19.2 Kbps, Local configuration via the Serial Configuration Utility
DeviceNet network
Standard DeviceNet protocol for all functions (not power-module power is provided independently), Available EDS file supports most DeviceNet compliant systems, Communication rate that is set automatically by bus master to 125 Kbps, 250 Kbps, or 500 Kbps,
Nonvolatile configuration
A copy of the module configuration is retained in nonvolatile memory from which the configuration is loaded upon powerup, The configuration that is stored in nonvolatile memory can be deleted only by a module-reset,command that is sent via a serial interf
Documents
Product Cutsheet General
--
1440-td001_-en-p Technical Data
1440-TD001
1440-um001_-en-p User Manual
1440-UM001
Type Resource Publication
General Product Cutsheet --
Technical Data 1440-td001_-en-p 1440-TD001
User Manual 1440-um001_-en-p 1440-UM001
Looking for more documentation?
Find curated technical documentation for this product in the Technical Documentation Center, or search our full Literature Library.
Search the Literature Library
Downloads
Available Downloads
  • Firmware for 1440-SDM02-01RA v8.000
See All Downloads
Certifications
China CCC
  • China CCC
  • MOROCCO DOC

This product was certified with the above certifications as of 2025-07-19. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Alternative Products
Items Per Page:
1-1 of 1
Technotes
Looking for more Technotes?
Find questions and answers from Rockwell Automation technical experts for this product in our Knowledgebase.
Search Knowledgebase
Loading
Find your nearest distributor
Contact your distributor in {0}
Change location
EmailEmail
PhonePhone
Find a partner
XM-124 Standard Dynamic Measurement Mdl
CloseClose
1440-SDM02-01RA
Close
Print
Chevron LeftChevron Left
Allen-Bradley 1440-SDM02-01RA product image
Chevron LeftChevron Left
Allen-Bradley 1440-SDM02-01RA product image
Allen-Bradley 1440-SDM02-01RA product image
Phone:
Call
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
Sign in to your Rockwell Automation account to submit a repair documentation request.
Sign In
Request repair documentation
All fields with * are required for processing your request.
This field is required
This field is required
This field is required
This field is required
This field is required
Documentation of liability insurance is required for anyone who is requesting documentation for product repairs.
UploadUpload
Please upload documentation of liability insurance.*
1 file selected
CloseClose
File size is too large. Must be less than 5 MB.
Accepted file types: zip, pdf; Maximum size: 5 MB.
Right to Repair Terms and Conditions
Rockwell Automation is making, parts, and service documentation available at your request in compliance with applicable right to repair laws and regulations. By signing below, you are agreeing to the following terms and conditions of your purchase of Rockwell Automation genuine repair parts for repair of a Rockwell Automation product. As used below, “Self Service Repair Parts” means genuine Rockwell Automation parts (components of Rockwell Automation products) purchased from Rockwell Automation for installation in a Rockwell Automation product as part of a Self Service Repair. Self Service Repair Parts may be new or previously used genuine Rockwell Automation parts that have been tested and passed Rockwell Automation functional requirements. “Self Service Repair Tools” means equipment and related materials purchased for the purpose of performing repairs.
Your request has been successfully submitted.
Please allow up to 5 business days to receive a response to your inquiry.
  1. Chevron LeftChevron Left Rockwell Automation Home
  2. Chevron LeftChevron Left Products
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose