Loading

Privilege Escalation Vulnerability in Pavilion8®

Severity:
High
Advisory ID:
SD1681
Veröffentlichungsdatum:
July 16, 2024
Zuletzt aktualisiert:
November 20, 2024
Revision Number:
1.0
Known Exploited Vulnerability (KEV):
Nein
Corrected:
Ja
Workaround:
Nein
CVE IDs
CVE-2024-6435
Downloads
The following link(s) provide the security advisory in Vulnerability Exploitability Exchange format:
CVE-2024-6435
Zusammenfassung
Privilege Escalation Vulnerability in Pavilion8®

Published Date: July 16, 2024 
Last updated: July 16, 2024

Revision Number: 1.0

CVSS Score: v3.1: 8.8/10, v4.0: 8.7/10

 

The security of our products is important to us as your chosen industrial automation supplier. This anomaly was found internally during routine testing and is being reported based on our commitment to customer transparency and to improve their business or production environments.

 

AFFECTED PRODUCTS AND SOLUTION

 

 

Affected Product

 

 

 

 

First Known in Software Version(s)

 

 

 

 

Corrected in Software Revision

 

 

 

 

Pavilion8® 

 

 

 

 

v5.15.00 
v5.15.01 
v5.16.00 
v5.17.00 
v5.17.01

 

 

v5.20.00

 

 

 

 

v6.0

 

 

 

Mitigations and Workarounds 

Users using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.  

  • Limit access to only users who need it. 

  • Periodically review user access and privileges to confirm accuracy. 

  • Security Best Practices

VULNERABILITY DETAILS

Rockwell Automation used version 3.1 and 4.0 of the CVSS scoring systems to assess the following vulnerabilities.  

CVE-2024-6435 IMPACT

A privilege escalation vulnerability exists in the affected products which could allow a malicious user with basic privileges to access functions which should only be available to users with administrative level privileges. If exploited, an attacker could read sensitive data, and create users. For example, a malicious user with basic privileges could perform critical functions such as creating a user with elevated privileges and reading sensitive information in the “views” section.  

CVSS 3.1 Base Score: 8.8/10

CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

CVSS 4.0 Base Score: 8.7/10

CVSS Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CWE-732: Incorrect Permission Assignment for Critical Resource

Known Exploited Vulnerability (KEV) database:  No

Customers can use Stakeholder-Specific Vulnerability Categorization to generate more environment specific prioritization.

 ADDITIONAL RESOURCES

  • JSON CVE-2024-6435

Rockwell Automation Home
Copyright ©2022 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation Startseite Chevron RightChevron Right
  2. Chevron LeftChevron Left Trust Center Chevron RightChevron Right
  3. Chevron LeftChevron Left Industrial Security Adv Chevron RightChevron Right
  4. Chevron LeftChevron Left Industrial Security Advisory Detail Chevron RightChevron Right
Bitte aktualisieren Sie Ihre Cookie-Einstellungen, um fortzufahren.
Für diese Funktion sind Cookies erforderlich, um Ihr Erlebnis zu verbessern. Bitte aktualisieren Sie Ihre Einstellungen, um diese Cookies zuzulassen:
  • Social-Media-Cookies
  • Funktionale Cookies
  • Leistungscookies
  • Marketing-Cookies
  • Alle Cookies
Sie können Ihre Einstellungen jederzeit aktualisieren. Weitere Informationen finden Sie in unserem Datenschutzrichtlinie
CloseClose